The development of new techniques for partial discharge monitoring and location in high voltage underground power cables. Increased utilization factors have caused a significant increase in the loading of high voltage distribution cables. This increased loading subjects cable insulation to increased stress which can degrade the insulation, cause cable failure and power loss to consumers. On-line cable insulation monitoring is required and partial discharge monitoring in cables provides a viable ....The development of new techniques for partial discharge monitoring and location in high voltage underground power cables. Increased utilization factors have caused a significant increase in the loading of high voltage distribution cables. This increased loading subjects cable insulation to increased stress which can degrade the insulation, cause cable failure and power loss to consumers. On-line cable insulation monitoring is required and partial discharge monitoring in cables provides a viable technique, but technical problems have prevented its application in on-line operation.
This project will develop techniques for such on-line monitoring. High frequency electrical sensors will be used to reduce interference and improve signal levels. Both a coarse alarm and a higher sensitivity monitor will be developed.
Read moreRead less
Developing a Smart Monitoring System for Leakage Currents from Insulators on Wooden Poles. Numerous wooden poles are used for electricity power transmission in urban and rural areas of Australia. Insulators suspended on poles are subject to contamination and moisture that cause partial discharge currents to flow through the wooden poles, resulting in pole fires leading to loss of power to customers and possible bush fires. This project aims at studying the characteristics of leakage currents fr ....Developing a Smart Monitoring System for Leakage Currents from Insulators on Wooden Poles. Numerous wooden poles are used for electricity power transmission in urban and rural areas of Australia. Insulators suspended on poles are subject to contamination and moisture that cause partial discharge currents to flow through the wooden poles, resulting in pole fires leading to loss of power to customers and possible bush fires. This project aims at studying the characteristics of leakage currents from insulators on wooden poles in Australian conditions and developing a smart monitoring system to detect and prevent pole fires caused by leakage currents. The outcomes will reduce the risk of pole fires, hence improving public safety, reliability of power supply and sustainability of the Australian power industry.Read moreRead less