Behaviour and innovative design of drive-in steel storage racks. Drive-in steel storage racks offer the most space-effective solution to storage needs. They have become increasingly sought after as population growth concentrates in the main Australian metropolitan areas, which is pushing up the cost of land and storage. However, the high failure rate of drive-in racking systems is costly to society, as they cause disruptions to our production and supply cycles, and lead to increased costs to Aus ....Behaviour and innovative design of drive-in steel storage racks. Drive-in steel storage racks offer the most space-effective solution to storage needs. They have become increasingly sought after as population growth concentrates in the main Australian metropolitan areas, which is pushing up the cost of land and storage. However, the high failure rate of drive-in racking systems is costly to society, as they cause disruptions to our production and supply cycles, and lead to increased costs to Australian industry and the consumer of the final product. There are great national benefits to be gained from developing innovative drive-in storage systems which have minimum risk of structural failure. Such systems will also enhance the international competitiveness of the Australian rack manufacturing industry.Read moreRead less
Structural Systems with Hollow Flange Sections in Cold-Formed Steel. Palmer Tube Mills have created a new range of hollow flange sections in cold-formed steel manufactured with the unique dual resistance welding process for use in the construction industry. The new sections combine the properties of hot-rolled open sections and cold-formed sections to create more structurally efficient sections. These new sections experience some unique and specific failure modes that are not considered in cur ....Structural Systems with Hollow Flange Sections in Cold-Formed Steel. Palmer Tube Mills have created a new range of hollow flange sections in cold-formed steel manufactured with the unique dual resistance welding process for use in the construction industry. The new sections combine the properties of hot-rolled open sections and cold-formed sections to create more structurally efficient sections. These new sections experience some unique and specific failure modes that are not considered in current design standards. This project will investigate these failure modes to devise efficient and safe guidelines for their structural design. The project will also develop new structural systems to utilise the unique properties of these sections.Read moreRead less
High-strength formwork systems. The project will lead to new formwork systems which are safer, stronger and quicker to erect. The systems will rely on scientific investigations to minimise the risk of structural collapse and associated cost to community. The systems are innovative and combine advanced technology to produce a superior product with strong export potential and capacity to raise the level of efficiency in the national market. The project will also develop advanced analysis and desig ....High-strength formwork systems. The project will lead to new formwork systems which are safer, stronger and quicker to erect. The systems will rely on scientific investigations to minimise the risk of structural collapse and associated cost to community. The systems are innovative and combine advanced technology to produce a superior product with strong export potential and capacity to raise the level of efficiency in the national market. The project will also develop advanced analysis and design methods for formwork systems which can be applied more generally to advance Australian engineers' position as world leaders in innovative structural design.Read moreRead less
An Integrated Systems Analysis: Fire Growth and Severity in Enclosures. An integrated systems risk-based model for fire safety has been developed and has been internationally acclaimed. A new fire severity submodel urgently needs to be developed before ramifications of the World Trade Centre catastrophe impact on fire safety regulations. Current submodels seriously misrepresent the real fires. They were developed from 1970's experiments on 2-3 metre cube-like enclosures and predict that fires ....An Integrated Systems Analysis: Fire Growth and Severity in Enclosures. An integrated systems risk-based model for fire safety has been developed and has been internationally acclaimed. A new fire severity submodel urgently needs to be developed before ramifications of the World Trade Centre catastrophe impact on fire safety regulations. Current submodels seriously misrepresent the real fires. They were developed from 1970's experiments on 2-3 metre cube-like enclosures and predict that fires engulf enclosures. Recent preliminary experiments have revealed that real fires burn locally at windows and only appear to be all engulfing. The research will lead international collaboration involving extensive experiments and some modelling to be completed in twelve months.Read moreRead less