Effects Of Pin Biomechanics, Coating Material And Surface Roughness On The Pin-bone Interface In External Repair
Funder
National Health and Medical Research Council
Funding Amount
$470,000.00
Summary
Some fractures require external fixation, anchored with metal pins in the bone fragments. The reatment is generally successful, although the pin tracts often loosen and become infected. This complication may jeopardise fracture healing and must be treated. The purpose of this project is to determine what aspects of pin design predispose to these problems at the pin-bone interface. Is it the way the pins are initially inserted, perhaps not tightly enough so that the pin is unstable, or perhaps to ....Some fractures require external fixation, anchored with metal pins in the bone fragments. The reatment is generally successful, although the pin tracts often loosen and become infected. This complication may jeopardise fracture healing and must be treated. The purpose of this project is to determine what aspects of pin design predispose to these problems at the pin-bone interface. Is it the way the pins are initially inserted, perhaps not tightly enough so that the pin is unstable, or perhaps too tight, causing microcracks in the bone? Is it the material of the pin, which might be improved with a bioactive coating? Is it the surface roughness which causes different responses of bone cells? Would it help to have an antibiotic pin? This proposal is designed to answer these questions. The biomechanics of the pin will first be studied with computer models and then tested in the laboratory. The loosening and infection associated with different types of pin will then be studied biologically. The results of the study will clarify the roles of pin biomechanics, coating and surface roughness, leading to improvements in design and better outcomes in fracture patients.Read moreRead less
A Novel Device To Improve Renal Blood Flow In Cardiorenal Syndrome
Funder
National Health and Medical Research Council
Funding Amount
$198,900.00
Summary
The aim of this project is to assist in the development of a novel device to treat poor delivery of blood to the kidneys in conditions such as heart muscle weakness (chronic heart failure, CHF). Specifically we aim to build a prototype and test the device in a relevant animal model of CHF. Chronic heart failure is a major public health problem affecting >10% of the adult population over the age of 60 years. It is associated with high morbidity, mortality, frequent hospitalisation and major co ....The aim of this project is to assist in the development of a novel device to treat poor delivery of blood to the kidneys in conditions such as heart muscle weakness (chronic heart failure, CHF). Specifically we aim to build a prototype and test the device in a relevant animal model of CHF. Chronic heart failure is a major public health problem affecting >10% of the adult population over the age of 60 years. It is associated with high morbidity, mortality, frequent hospitalisation and major cost burden on the public health system. Weak heart muscle results in poor delivery of blood to the kidneys. Poor delivery to the kidneys activates circulating hormones which in turn further impair cardiac function by adverse effects on the heart. We have developed and patented a novel catheter based system for improvement of renal function via a purpose built device. Proof-of-concept studies have shown that the device should improve kidney blood flow in the setting of CHF. Given the huge public health problem of heart failure and the importance of the kidney in this setting, the commercial potential for a simple device that can be positioned via a catheter-based approach, permanently implanted is large. The device is currently being constructed by the Monash University Department of Engineering where expertise exists with regard to biomedical devices and materials engineering. A series of proof-of-concept studies will then be performed in sheep, as the vasculature of the sheep roughly approximates the dimensions of man. Sheep with CHF will have the device inserted percutaneously into the aorta. Measurements will be made of renal artery flow, relevant circulatory hormones and ultrasound of the heart at baseline (pre-deployment) and following deployment. We believe the above studies (should they be successful) will be sufficient to constitute definitive proof-of-concept and thus allow the device to be commercialised, most likely by a licensing arrangement with a device company.Read moreRead less
Reducing The Burden Of Joint Replacement: An Innovative Biofeedback Device For Post-Surgical Rehabilitation.
Funder
National Health and Medical Research Council
Funding Amount
$169,500.00
Summary
This project aims to develop a robust wearable device capable of providing immediate audible feedback with respect to knee motion for enhanced post-knee replacement surgery rehabilitation, suitable for use by older people both independently and supervised at home or in the clinic. As there is a current unmet need for such wearable biofeedback devices, this project will lead to intellectual property generation, strengthened partnerships between the involved parties and identification of an indust ....This project aims to develop a robust wearable device capable of providing immediate audible feedback with respect to knee motion for enhanced post-knee replacement surgery rehabilitation, suitable for use by older people both independently and supervised at home or in the clinic. As there is a current unmet need for such wearable biofeedback devices, this project will lead to intellectual property generation, strengthened partnerships between the involved parties and identification of an industry partner to commercialise the technology.Read moreRead less
Development Of A Smart Arthroscopy System And Prototype Probe For Joint Tissues
Funder
National Health and Medical Research Council
Funding Amount
$230,632.00
Summary
This project relates to the ever growing use of arthroscopy in the management of joint defects. An innovative probe that will combine all the molecular, microstructural and biomechanical characteristics of joint articular cartialge and bone for the purposes of diagnosis, treatment, treatment-related decisions, comparison of the effectiveness of treament methods and post treatment evaluation will be developed. This system will produce spin-offs for artrhoscopy of other soft tissues and bodies.