X-ray Ghost Imaging and Tomography. This project aims to achieve safer, faster, and cheaper 3D X-ray imaging through a technique known as ghost imaging. X-ray imaging provides valuable information about internal structures, however, X-rays are carcinogenic and exposure (or dose) should be limited. Ghost imaging is an unconventional technique developed with visible light that has many potential benefits over conventional imaging. This research group are world leaders in ghost imaging and expect t ....X-ray Ghost Imaging and Tomography. This project aims to achieve safer, faster, and cheaper 3D X-ray imaging through a technique known as ghost imaging. X-ray imaging provides valuable information about internal structures, however, X-rays are carcinogenic and exposure (or dose) should be limited. Ghost imaging is an unconventional technique developed with visible light that has many potential benefits over conventional imaging. This research group are world leaders in ghost imaging and expect to develop software and hardware techniques to realise its potential and extend it to ghost tomography. The focus of this project is on reducing cancer risk in medical imaging, and allowing real-time quality control for 3D printing in safety-critical industries such as aerospace.Read moreRead less
Unlocking the potential of quantitative x-ray micro-tomography. This project aims to build on two new ideas in data acquisition and 3D image reconstruction to bring 3D X-ray microscopy or computed tomography (CT) into advanced research use as well as common industrial applications. In the past 10 years, CT has improved our understanding in areas ranging from the evolution of life and osteoporosis to composite material failure and oil recovery. However, the full potential of CT remains unrealised ....Unlocking the potential of quantitative x-ray micro-tomography. This project aims to build on two new ideas in data acquisition and 3D image reconstruction to bring 3D X-ray microscopy or computed tomography (CT) into advanced research use as well as common industrial applications. In the past 10 years, CT has improved our understanding in areas ranging from the evolution of life and osteoporosis to composite material failure and oil recovery. However, the full potential of CT remains unrealised because crucial features in structure and composition are overlooked by simplistic algorithms. Users cannot directly capture quantities of interest such as key compositional variation or defects, and workflows are poorly adapted for large-scale use in industrial fabrication or phenomics. This project aims to address these shortcomings using advanced mathematics and algorithms.Read moreRead less
Linkage Infrastructure, Equipment And Facilities - Grant ID: LE240100092
Funder
Australian Research Council
Funding Amount
$1,100,000.00
Summary
Quantum microscopy facility for ultrasensitive nanoscale magnetic imaging. Investigations of 2D and van der Waals materials, biological samples, energy materials, and quantum devices on the nano- and microscale are revolutionising medicine, communications, information technology, energy production and storage by virtue of new phenomena. The new quantum microscopy facility will enable state-of-the-art capabilities in mapping chemical, magnetic, optical, electronic, and spectral properties, provid ....Quantum microscopy facility for ultrasensitive nanoscale magnetic imaging. Investigations of 2D and van der Waals materials, biological samples, energy materials, and quantum devices on the nano- and microscale are revolutionising medicine, communications, information technology, energy production and storage by virtue of new phenomena. The new quantum microscopy facility will enable state-of-the-art capabilities in mapping chemical, magnetic, optical, electronic, and spectral properties, providing cutting-edge tools that will enable breakthroughs in both existing and future multi-disciplinary projects in photonics, quantum devices, nanomaterials, nanoelectronics, biotechnology, and energy technology as key drivers of the new economy in Australia.Read moreRead less
Linkage Infrastructure, Equipment And Facilities - Grant ID: LE0454166
Funder
Australian Research Council
Funding Amount
$1,305,029.00
Summary
Nanoscale Materials Characterization Facility. We request a transmission and a scanning electron microscope, each with specialist electron probes smaller than a nanometre, which can selectively analyse the atomic structure and chemistry of sub-nanometre regions of material.
These capabilities are essential to advance a large range of research projects at the cutting-edge of materials science and engineering, undertaken by Victoria's leading research institutions: five Victorian universities, ....Nanoscale Materials Characterization Facility. We request a transmission and a scanning electron microscope, each with specialist electron probes smaller than a nanometre, which can selectively analyse the atomic structure and chemistry of sub-nanometre regions of material.
These capabilities are essential to advance a large range of research projects at the cutting-edge of materials science and engineering, undertaken by Victoria's leading research institutions: five Victorian universities, the CSIRO, Nanotechnology Victoria Ltd, the Victorian Centre for Advanced Materials Manufacturing and the CRC for Microtechnology. Together they have contributed $2.58 million to this project.
This state-of-the-art facility will include the highest spatial resolution microscope in Australia.
Read moreRead less
Linkage Infrastructure, Equipment And Facilities - Grant ID: LE0347403
Funder
Australian Research Council
Funding Amount
$222,000.00
Summary
An ultra-wideband digital filterbank for the Mopra Radiotelescope. We seek funding to equip the Mopra radiotelescope with an ultra-wide-bandwidth digital filter bank. This will greatly improve the efficiency of the observatory, increasing the speed at which spectroscopic data is acquired by a factor of 8, and the speed of acquiring continuum data by a factor of 32. Once equipped in this way, Mopra, which is already the largest millimetre-wave radiotelescope in the southern hemisphere, will enjo ....An ultra-wideband digital filterbank for the Mopra Radiotelescope. We seek funding to equip the Mopra radiotelescope with an ultra-wide-bandwidth digital filter bank. This will greatly improve the efficiency of the observatory, increasing the speed at which spectroscopic data is acquired by a factor of 8, and the speed of acquiring continuum data by a factor of 32. Once equipped in this way, Mopra, which is already the largest millimetre-wave radiotelescope in the southern hemisphere, will enjoy an unbeatable edge over all other competing observatories around the world through its combination of collecting area and bandpass.Read moreRead less
Linkage Infrastructure, Equipment And Facilities - Grant ID: LE0989127
Funder
Australian Research Council
Funding Amount
$400,000.00
Summary
A High-Throughput Neutron Spectrometer for The Study of Atomic and Molecular Motion at ANSTO. Neutron scattering enables new science across a broad range of disciplines, and for this reason it is undergoing major expansion in the USA, Europe, Japan and Australia. Various diffactometers and spectrometers have recently been built at ANSTO, but an instrumental option for a high-throughput cross-discipline spectroscopy is urgently needed. Fortunately, it is fairly straightforward to add this type of ....A High-Throughput Neutron Spectrometer for The Study of Atomic and Molecular Motion at ANSTO. Neutron scattering enables new science across a broad range of disciplines, and for this reason it is undergoing major expansion in the USA, Europe, Japan and Australia. Various diffactometers and spectrometers have recently been built at ANSTO, but an instrumental option for a high-throughput cross-discipline spectroscopy is urgently needed. Fortunately, it is fairly straightforward to add this type of option to an existing spectrometer that will broaden its user-base from specialised applications in physics to more general applications in physics, chemistry, materials-science and biology. This additional option provides a totally new way for Australian scientists to study atomic and molecular motions. Read moreRead less
Linkage Infrastructure, Equipment And Facilities - Grant ID: LE0237527
Funder
Australian Research Council
Funding Amount
$170,000.00
Summary
Bioscope IV : Advanced Scanned Probe Microscopy. The Atomic Force Microscope presents a unique view of the microscopic and molecular world, for it is sensitive to force alone. This instrument can accurately map force over a surface at the molecular scale; picoNewtons at nanometre resolution. The host of intermolecular forces which cause phenomena such as self-assembly, colloid stability, cell interactions and friction are only directly measurable with this technique. In this field of force meas ....Bioscope IV : Advanced Scanned Probe Microscopy. The Atomic Force Microscope presents a unique view of the microscopic and molecular world, for it is sensitive to force alone. This instrument can accurately map force over a surface at the molecular scale; picoNewtons at nanometre resolution. The host of intermolecular forces which cause phenomena such as self-assembly, colloid stability, cell interactions and friction are only directly measurable with this technique. In this field of force measurement Australian researchers are leaders. The proposed instrument expands the capabilities of this effort, and develops exciting new directions including the direct manipulation of molecules through a novel feedback and control (haptic) interface.Read moreRead less
Linkage Infrastructure, Equipment And Facilities - Grant ID: LE0346515
Funder
Australian Research Council
Funding Amount
$507,000.00
Summary
Fluorescence Detector for the Australian National Beamline Facility. X-ray absorption spectroscopy (XAS) is an extremely important synchrotron radiation tool for determining the local structure around an X-ray absorbing atom. This has many applications in the study of materials, minerals, metal complexes, and metalloproteins and can often be used to obtain information that is not available by other techniques, because structural information can be obtained in the solid or solution state and in ....Fluorescence Detector for the Australian National Beamline Facility. X-ray absorption spectroscopy (XAS) is an extremely important synchrotron radiation tool for determining the local structure around an X-ray absorbing atom. This has many applications in the study of materials, minerals, metal complexes, and metalloproteins and can often be used to obtain information that is not available by other techniques, because structural information can be obtained in the solid or solution state and in mixtures. The current proposal is aimed at introducing new technology into the Australian National Beamline Facility that will greatly improve the quality and quantity of experiments that can be performed and extend studies into dilute solutions and protein samples.Read moreRead less
Linkage Infrastructure, Equipment And Facilities - Grant ID: LE0989915
Funder
Australian Research Council
Funding Amount
$127,000.00
Summary
X-ray Nano-scale Coherence Facility. Australia is rapidly developing into a world leader for x-ray imaging. This position has been supported by leading research groups and more recently by the development of the Australian Synchrotron. This project will fill a vital missing link in the experimental capability of Australian researchers - a flexible facility that can provide a nanoscale x-ray source. This enhanced capability will lead to new developments in coherent imaging methods. These new meth ....X-ray Nano-scale Coherence Facility. Australia is rapidly developing into a world leader for x-ray imaging. This position has been supported by leading research groups and more recently by the development of the Australian Synchrotron. This project will fill a vital missing link in the experimental capability of Australian researchers - a flexible facility that can provide a nanoscale x-ray source. This enhanced capability will lead to new developments in coherent imaging methods. These new methods will be used in the study of biological systems, leading to better drug design as well as in the study of materials, leading to stronger and lighter components. Read moreRead less