Biological, Functional And Radiographic Evaluation Of Autologous Chondrocyte Implantation
Funder
National Health and Medical Research Council
Funding Amount
$307,400.00
Summary
We will test the hypothesis that autologous chondrocyte implantation (ACI) and extensor realignment produces superior clinical, biological and radiographic results when compared with conventional treatment of realignment and debridement. We will specifically address the following aims: 1. Quantify the clinical outcome of ACI compared to the traditionally used treatment of debridement through the use of functional evaluation in a blinded randomised controlled clinical trial; 2. Evaluate the radio ....We will test the hypothesis that autologous chondrocyte implantation (ACI) and extensor realignment produces superior clinical, biological and radiographic results when compared with conventional treatment of realignment and debridement. We will specifically address the following aims: 1. Quantify the clinical outcome of ACI compared to the traditionally used treatment of debridement through the use of functional evaluation in a blinded randomised controlled clinical trial; 2. Evaluate the radiographic changes in the patellofemoral joint that occur as a result of ACI, using high resolution magnetic resonance imaging (MRI) to quantify the regeneration of hyaline articular cartilage; 3. Using the new technique of confocal arthroscopy, we will compare the histologic appearances of the ACI graft and its interface with adjacent articular cartilage; 4. Evaluate patient, surgical and explant chondrocyte characteristics in relation to functional, radiographic and biological outcomes. With respect to the matrix-induced autologous chondrocyte implantation (MACI) technique, we wish to clarify the clinical practice as a definitive treatment for articular cartilage defects. This will be the first randomised, controlled clinical trial of the MACI technique compared to that used by other groups. A positive clinical outcome from this trial will help promote the three cornerstones of this procedure – successful cell culture, efficient surgical procedures, and complimentary postoperative rehabilitation. Furthermore, this research will: a) Enhance the expansion of the MACI technique; b) Encourage development of endoscopic techniques of implantation using a combination of – • Preoperative defect registration with MRI • pre-cut custom patches, implanted with • Computer-assisted navigation techniques: c) Increase the potential to cater for a larger number of patients requiring articular cartilage repair; d) Confirm the long-term durability of regenerated cartilage in the 4th year and beyond; e) Add further commercial value by demonstrating MACI may prevent the onset of osteoarthritis.Read moreRead less
We will seek to address an important clinical problem in orthpaedics, namely the bone loss that commonly occurs around joint replacement prostheses. Termed peri-prosthetic osteolysis (PO), this bone loss can result in the loosening and ultimate failure and need for revision of the artificial joint components. PO is thought to be caused by the body's reaction to wear particles generated from the articulating surface of the prosthesis. However, it has not previously been possible to accurately exp ....We will seek to address an important clinical problem in orthpaedics, namely the bone loss that commonly occurs around joint replacement prostheses. Termed peri-prosthetic osteolysis (PO), this bone loss can result in the loosening and ultimate failure and need for revision of the artificial joint components. PO is thought to be caused by the body's reaction to wear particles generated from the articulating surface of the prosthesis. However, it has not previously been possible to accurately explore the relationship between prothesis wear and PO, or the progression of PO, because of a lack of techniques to image and measure the volume of PO around metal prosthesis components. We have developed a means to accurately and reproducibly measure the volume of bone loss, using CT, and will do so longitudinally in joint replacement patients to obtain the first information about the progression of PO. New computer based methods will be used concurrently to relate prosthesis wear and migration parameters to PO. Patients who come to surgery for replacement of failed prostheses will be investigated further by analysis of the tissues involved in the bone loss around prostheses. Basic science experiments will seek to understand the underlying causes of PO and the findings will be important in interpreting the clinical results. An animal model will be used to seek approaches to inhibiting the pathological response to wear particles. The significance of these studies is that they will lead to improved outcomes for joint replacement patients, increasing the interval to revision surgery, which is both extremely costly and brings an attendant morbidity and mortality.Read moreRead less
Impaired Bone Remodelling Leads To Failure Of Orthopaedic Prostheses
Funder
National Health and Medical Research Council
Funding Amount
$515,917.00
Summary
The failure of bone prostheses is becoming a major health problem. More than 26,000 hip, and an equal number of knee, replacements were performed in Australia in 2002 with the number increasing between 5%-10% each year for the previous 10 years. Disturbingly, the incidence of revision hip surgery in Australia is now more than 15%, meaning that, despite the impressive success of joint replacement surgery, a significant number of arthroplasties fail. It is becoming more common for young, active in ....The failure of bone prostheses is becoming a major health problem. More than 26,000 hip, and an equal number of knee, replacements were performed in Australia in 2002 with the number increasing between 5%-10% each year for the previous 10 years. Disturbingly, the incidence of revision hip surgery in Australia is now more than 15%, meaning that, despite the impressive success of joint replacement surgery, a significant number of arthroplasties fail. It is becoming more common for young, active individuals to receive joint replacement surgery to improve their quality of life. This, combined with increasing life expectancy, and the known higher rate of failure of joint replacements in younger patients, means that the morbidity of a failed replacement, and the mobidity and associated mortality of revision surgery, will become an increasingly important health issue, with a major impact upon health budgets. The overwhelming majority of hip and knee prostheses have metal or ceramic on polyethylene bearing surfaces. It is now apparent that most implants fail due to bone loss around them leading to loosening, and evidence is accumulating that polyethylene wear particles are a major contributing factor to this process. It is therefore vital that we obtain better understanding of the causes of implant failure in order to extend the life of these implants and this project is designed to do so.Read moreRead less
Regulation Of Key Pathways Causing Peri-implant Bone Loss.
Funder
National Health and Medical Research Council
Funding Amount
$403,639.00
Summary
The failure of bone prostheses is becoming a major health problem in our aging population. Despite the impressive success of joint replacement surgery, a significant number of arthroplasties fail. It is now apparent that most implants fail due to bone loss around them which leads to loosening. This project aims to obtain a better understanding of the causes of implant failure and find ways to extend the life of these implants .
Radiostereometric Analysis Of The Effect Of A Large Articulation On Prosthetic Wear And Migration After Hip Replacement
Funder
National Health and Medical Research Council
Funding Amount
$192,186.00
Summary
At total hip replacement, there has been a recent trend to use prostheses with a larger ball and liner in the socket. This may decrease the risk of post-operative dislocation, but may also increase the amount of wear, leading to bone loss and loosening of prostheses, which may then require replacement. This project will use a special type of x-ray to determine whether wear and movement of these new prostheses is clinically acceptable, so that they can be used with confidence in patients.